We have provided supreme quality of Digital Photo Colorimeter for satisfaction of our clients. Superior quality
raw material and advanced technology are used to manufacture them. Customized solutions and timely
completion of work give our products the added incentive. Also, they can also be used for analysis of
Wavelength range: 400 to 700 nm
Resolution:0.01
Absorbance: 0 – 1.99a
Photo detector: silicon photodiode/photo cell
Display: 2 1⁄2 digit led
Light source: 6.8v, 0.3 amp. Tungsten lamp
Sample system: 10mm path length matched glass test tubes High std.glass
filters: 8 filters Filters: 400,420,480,500,520,540,620,680 nm
Weight: 3 kg (approx.)
Power supply: 230v ac ± 10% , 50hz with in-built stabilizer
Accessories: test tube set of 5, spare light source, dust cover, Instruction manual
We have provided supreme quality of AUTO Photo Colorimeter for satisfaction of our clients. Superior quality
raw material and advanced technology are used to manufacture them. Customized solutions and timely
completion of work give our products the added incentive. Also, they can also be used for analysis of
Wavelength range: 400 to 700 nm
Resolution:0.01
Absorbance: 0 – 1.99a
Photo detector: silicon photodiode/photo cell
Display: 2 1⁄2 digit led
Light source: 6.8v, 0.3 amp. Tungsten lamp
Sample system: 10mm path length matched glass test tubes High std.glass
filters: 8 filters Filters: 400,420,480,500,520,540,620,680 nm
Weight: 3 kg (approx.)
Power supply: 230v ac ± 10% , 50hz with in-built stabilizer
Accessories: test tube set of 5, spare light source, dust cover, Instruction manual
Microprocessor Photo Colorimeter GI-123 is a compact and easy to operate instrument for Photo Colorimeter analysis of any connotation. The output is available on a 3 digit seven segment red LED display in terms of % Transmission (%T), Absorbance (Abs.), and Concentration (Conc.) and K Factor. This is a unique system that combines convenience with accuracy and precision in analysis.
The instrument includes a wide range of flters covering wavelength from 420-680 nm in the form of in-built filters. The instrument confirms to aII generaI & safety standards.
Wavelength Range : 400 - 700nm
Filter System: In-built filter disc with 8 standard filters
Sample Volume: 1 ml
Sample System: 10 mm path-length matched glass test tubes
Detector: Silicon Photodiode
Display: 3 Digit 7-Segment Red LED Display
Light Sources: 3V LED 100 MA
Readout: %T: 0 - 100. Abs: 0 -1.99, Conc.: 1- 999. K Factor: 1 - 999
Power Supply: 230 V :t 10% AC, 50Hz
Weight: 2.5 Kg. (Approx.)
Features: -
· High Stability and Accuracy
· Slop Control
· 3.5 Digit LED Display
· Properly Tested
Technical Specifications: -
Model No.: GI-128
Display: 3.5-digit LED
Resolution: 0.01 pH, 1 mV
Range: 0 to 14.00 pH
Calibration: 2 Point (4pH, 7pH)
Accuracy: ± 0.01 pH, ± 1 mV
Temperature: Manual 0 to 100 Degree Celsius
Slope Correction: 80 to 120%
Power Supply: 230V, ± 10% AC, 50 Hz
Dimension: 280X180X88 mm (LXBXH)
Weight: 3 KG
Accessories: -
· Combination pH Electrode
· Buffer Tablets (4pH, 7pH)
· pH Electrode Stand
· Instruction Manual,
Digital Flame Phootometer
GI-140
Range: Na: 0-100 ppm, K: 0-100 ppm,
Ca: 15-100 ppm (optional), Li: 10-100 ppm (Optional)
Sensitivity: Na: 5 ppm, K: 5 ppm,
Ca: 10 ppm (Optional), Li: 10 ppm (Optional)
Readout: 2.5 Digit Bright Red LED Display
Accuracy: +/- 2 % upto 40 ppm +/- 5% above 40 ppm
Ignition System: Auto Ignition System
Dimension: 385X245X200 mm
Measurement System: Measures one Eleent at a time
Repeatability" +/- 2 Counts
Detector: Silicon Photodiode
Filters: Narrow Band Interference Glass Filters
Nebulizer: Black Bakelite, Axial Flow Type
Flame System: LPG and Dry Oil Free Air
Warm up Time: Time 10 Minutes
Power Supply: 230V, +/-10 % AC, 50 Hz
Weight: 7.5 Kg (APPROX)
*FOR MORE DETAI;S ASK FOR CATALOG*
Microprocessor Flame Photometer
GI-141 & GI-671
Auto Gas Cutoff Facility
Auto Flame Failure Detection Facility
Inbuilt Thermal Printer
µP Based With Printer Interface
Five Element Measurement In Single Aspiration of the Sample
Curve Calibration Programmability using Maximum of 25 Standards
Data Processing Through Curve Fitting Techniques - Least Squares, Quadratic
Multiple Calibration Curves Saving Facility
Samples Data Storage Facility
Online Help Key
Printer Attachment Facility
Measurement in ppm & meq
Useful For Both Medical & Soil Testing Applications
Setup Storage Facility up to 1 D setups files
Supplied with Compressor Unit
*FOR MORE DETAI;S ASK FOR CATALOG*
Microprocessor Flame Photometer
GI-6710
Auto Gas Cutoff Facility
Auto Flame Failure Detection Facility
Inbuilt Thermal Printer
µP Based With Printer Interface
Five Element Measurement In Single Aspiration of the Sample
Curve Calibration Programmability using Maximum of 25 Standards
Data Processing Through Curve Fitting Techniques - Least Squares, Quadratic
Multiple Calibration Curves Saving Facility
Samples Data Storage Facility
Online Help Key
Printer Attachment Facility
Measurement in ppm & meq
Useful For Both Medical & Soil Testing Applications
Setup Storage Facility up to 1 D setups files
Supplied with Compressor Unit
*FOR MORE DETAI;S ASK FOR CATALOG*
COD Digestion Apparatus: GI-8216
COD Digestion Apparatus with Auto Time Control & Microprocessor Based PID Temperature Controller
In waste water treatment, the Chemical Oxygen Demand (COD) is an important measurement for the amount of oxygen that is required to break down pollutants (organic substances) in water
Features:
To Determination of chemical oxygen demand
Solid state block heated unit with provision for samples to be digested at a time.
36 mm diameter reaction vessels with 20 ml sample size to heat at temperatures of 150°C ± 1° C.
Supplied with air condensers, glass reaction vessels. Samples after being digested for 2 hours can be analyzed using calorimeter or conventional titration method.
To work on 220/230 Volts AC Supply
Block Dimension: 200 X 200 X 80 mm
No. of Cavity : 16
PID Temp. Controlled & Auto Timer Control: Ambient +5⁰C to 150⁰C
COD Digestion Apparatus: GI-8208
COD Digestion Apparatus with Auto Time Control & Microprocessor Based PID Temperature Controller
In waste water treatment, the Chemical Oxygen Demand (COD) is an important measurement for the amount of oxygen that is required to break down pollutants (organic substances) in water
Features:
To Determination of chemical oxygen demand
Solid state block heated unit with provision for samples to be digested at a time.
36 mm diameter reaction vessels with 20 ml sample size to heat at temperatures of 150°C ± 1° C.
Supplied with air condensers, glass reaction vessels. Samples after being digested for 2 hours can be analyzed using calorimeter or conventional titration method.
To work on 220/230 Volts AC Supply
Block Dimension: 200 X 100 X 80 mm
No. of Cavity : 8
PID Temp. Controlled & Auto Timer Control: Ambient +5⁰C to 150⁰C
COD Digestion Apparatus: GI-8204
COD Digestion Apparatus with Auto Time Control & Microprocessor Based PID Temperature Controller
In waste water treatment, the Chemical Oxygen Demand (COD) is an important measurement for the amount of oxygen that is required to break down pollutants (organic substances) in water
Features:
To Determination of chemical oxygen demand
Solid state block heated unit with provision for samples to be digested at a time.
36 mm diameter reaction vessels with 20 ml sample size to heat at temperatures of 150°C ± 1° C.
Supplied with air condensers, glass reaction vessels. Samples after being digested for 2 hours can be analyzed using calorimeter or conventional titration method.
To work on 220/230 Volts AC Supply
Block Dimension: 100 X 100 X 80 mm
No. of Cavity : 4
PID Temp. Controlled & Auto Timer Control: Ambient +5⁰C to 150⁰C